IEC 61753-1 Ed. 2.1:2020 (b)
光ファイバ相互接続装置及び受動部品-性能基準-第1部:一般及び手引
Fibre optic interconnecting devices and passive components - Performance standard - Part 1: General and guidance

発行年月日: 2020-06-24
状態: 有効
邦訳版: 無

規格概要
IEC 61753-1:2018+A1:2020 provides guidance for the drafting of performance standards for all passive fibre optic products. This document defines the tests and severities which form the performance categories or general operating service environments and identifies those tests which are considered to be product specific. Test and severity details are given in Annex A. This second edition cancels and replaces the first edition published in 2007. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) definitions updated with new products: wall outlets, wall or pole mounted boxes, splices, ODF modules, street cabinets, hardened connectors and field mountable connectors;
b) categories U and O are replaced by categories OP and OP+. No mandatory sequence in category OP+. Category OP+ contains the tests from category OP with the addition of only 4 other tests;
c) addition of Category I (Industrial);
d) temperature ranges added (with the HD suffix to the categories C, OP, OP+ and I) in case passive optical components are placed in a housing together with active electronics (HD stands for heat dissipation );
e) the height of category A changed from 3 m to ground level (0 m);
f) the lower level height of category G environment changed from ground level (0 m) to 1 m below ground level. Upper level remains at 3 m above ground level;
g) addition of performance tests, test severities and performance criteria for new products: Wall outlet, wall or pole mounted boxes, mechanical splices, fusion splice protectors, ODF modules, street cabinets, field mountable connectors and hardened optical connectors;
h) test severity of ""Mating durability"" test for connectors in categories C, OP ,OP+ and I is reduced to 200 cycles for connectors with cylindrical ferrules and 50 cycles for connectors with rectangular ferrules;
i) test severity of ""Change of