IEC 60601-2-33 Ed. 4.0:2022 (b)
医用電気機器-第2-33部:医療診断用のMR装置の基礎安全及び基本性能の特定要求事項
Medical electrical equipment - Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis
発行年月日:
2022-08-04
状態:
有効
邦訳版:
無
英語 302ページ
78,925 円(税込) 本体価格:71,750円
- 規格概要
-
IEC 60601-2-33:2022 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MAGNETIC RESONANCE (MR) EQUIPMENT and MAGNETIC RESONANCE (MR) SYSTEMS.全文を表示する
This document does not cover the application of MR EQUIPMENT beyond the INTENDED USE.
If a clause or subclause is specifically intended to be applicable to MR EQUIPMENT only, or to MR SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to MR EQUIPMENT and to MR SYSTEMS, as relevant.
This document does not formulate additional specific requirements for MR EQUIPMENT or MR SYSTEMS used in INTERVENTIONAL MR EXAMINATIONS.
IEC 60601-2-33:2022 cancels and replaces the third edition published in 2010, Amendment 1:2013 and Amendment 2:2015. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) aligned with IEC 60601-1:2005 and its two amendments IEC 60601-1:2005/AMD1:2012 and IEC 60601-1:2005/AMD2:2020;
b) addition of safety requirements for the EMERGENCY FIELD SHUT DOWN UNIT;
c) clarification of acoustic protection measures for the PATIENT and MR WORKER;
d) addition of noise emission declaration for exposure inside the MR EXAMINATION ROOM, to support occupational health assessment by the RESPONSIBLE ORGANIZATION;
e) addition of compliance methods for thermal safety of RF coils;
f) addition of RF transmit definitions to match MR CONDITIONAL labelling requirements for MEDICAL DEVICES;
g) clarification of requirements for MR CONDITIONAL labelling of ACCESSORIES;
h) alignment of static magnetic field limit for B0 HAZARD area to limits in other MEDICAL DEVICE standards (especially that for pacemakers, ISO 14117), the new limit value being 0,9 mT;
i) improved description of the magnetic field related plots in the Compatibility Technical Specification Sheet (CTSS);
TC |
TC 62/SC 62B |
---|---|
ICS |
11.040.55 |