IEC 60335-2-110 Ed. 2.0:2024 (b)
家庭用及び類似の電気機器-安全性-第2-110部:インサーション又は接触アプリケータをもつ業務用電子レンジの特定要求事項
Household and similar electrical appliances - Safety - Part 2-110: Particular requirements for commercial microwave appliances with insertion or contacting applicators

発行年月日: 2024-07-11
状態: 有効
邦訳版: 無

規格概要 IEC 60335-2-110:2024 is available as IEC 60335-2-110:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60335-2-110:2024 deals with the safety of microwave appliances intended for commercial use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances.
As far as is practicable, this standard deals with the common hazards presented by these types of appliances.
Appliances covered by this standard incorporate an open-ended applicator for treatment of the load. They are divided into three types:
- with insertion applicator, typically for moisture removal by insertion into holes in floors, walls or ceilings;
- with large area contacting applicator, typically for drying of floors, walls or ceilings;
- with small area contacting applicator, typically for paint removal and spot-heating.
Microwave appliances with insertion applicator, large area contacting applicator or small area contacting applicator are using electromagnetic energy in one or several of the ISM frequency bands between 300 MHz and 30 GHz, for supplying energy to an external load which is heated so that a resulting process of drying, moisture transport which can result in forces due to formation of steam, decomposition or chemical modification, melting, or termination of organisms such as bacteria or fungus occurs.
Appliances with insertion applicator and with large area contacting applicator are portable appliances. Appliances with small area contacting applicator are handheld appliances.
Appliances that use non-electrical energy are within the scope of this standard. The microwave-related portion is considered motor-operated.
The rationales for the microwave barrier and associated leakage test
TC TC 61/SC 61B